Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Table R803.1 is for roof sheathing which requires 5/8 plywood with rafters 24" o.c. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table 905.2.8.2. The installation of asphalt shingles shall comply with the provisions of this section. The International Residential Code (IRC) and the Residential Edition of the Florida Building Code (FBC) both refer to Table R503.2.1.1(1) of the APA Engineered Wood Construction Guide for specs. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. The installation of asphalt shingles shall comply with the provisions of this section. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. The second R-value applies when more than half of the insulation is on the interior of the mass wall. 12 oz/sq ft for preformed metal shingle systems. Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Mineral-surfaced roll roofing shall not be applied on roof. Stainless steel fasteners are acceptable for metal roofs. Sprayed polyurethane foam roofs shall have a design. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Mineral-surfaced roll roofing shall not be applied on roof. arrow_right. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Where the existing roof covering is slate, clay, cement or asbestos-cement tile. Asphalt shingles shall be fastened to solidly sheathed decks. Above-deck thermal insulation board shall comply with the standards in Table R906.2. IRC Section Table 301.5 Minimum Uniformly Distributed Live Loads: 2018 irc roof sheathing requirements. SECTION R802 WOOD ROOF FRAMING. Materials and methods of application used for re-covering or replacing an existing, The structural roof components shall be capable of supporting the, Roof replacement shall include the removal of existing layers of, Flashings shall be reconstructed in accordance with. The installation of wood shingles shall comply with the provisions of this section. Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Where the existing roof has two or more applications of any type of roof . or less. Foam plastic materials and installation shall comply with. Same as Maximum Ultimate Design Wind Speed, Apply in accordance with the manufacturer's, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B 370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet, ASTM B 209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum, Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, As an alternative, self-adhering polymer-modified bitumen, The standard calculations contained in ASTM D 7158 assume Exposure Category B or C and. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. Class A, B or C roofing shall be installed in, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. Asphalt shingles shall be used only on roof. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of wood shakes shall comply with the provisions of this section. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. 2018 IRC Simplified Wall Bracing Provisions 4 Objectives Upon completion, participants will be better able to: 1. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. The installation of modified bitumen roofing shall comply with the provisions of this section. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of wood shakes shall comply with the provisions of this section. Slate shingles shall be fastened to solidly sheathed roofs. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Asphalt shingles shall be used only on roof. Thermoplastic single-ply membrane roofs shall have a design. 2. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right Flashing and counterflashing shall be made with sheet metal. Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. 201 0 obj <> endobj Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. Foam plastic materials and installation shall comply with. Asphalt shingle packaging shall bear a, Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer, but not less than four fasteners per strip shingle or two fasteners per individual shingle. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Slate shingles shall comply with ASTM C406. Foam plastic materials and installation shall comply with. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Slate shingles shall be secured to the roof with two fasteners per slate. (914 mm). In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of asphalt shingles shall comply with the provisions of this section. The installation of liquid-applied roofing shall comply with the provisions of this section. Rooftop-mounted photovoltaic systems shall be installed in accordance with the manufacturer's instructions. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. The installation of mineral-surfaced roll roofing shall comply with this section. endstream endobj 202 0 obj <. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. A base sheet that complies with the requirements of. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Asphalt shingles shall be tested in accordance with ASTM D7158. Minimum headlap for slate shingles shall be in accordance with Table 905.6.5. Drip edges shall extend not less than. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. The installation of liquid-applied roofing shall comply with the provisions of this section. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, In areas where the average daily temperature in January is 25F (-4C) Asphalt shingles shall be tested in accordance with ASTM D7158. The installation of slate shingles shall comply with the provisions of this section. Asphalt shingle packaging shall bear a. (R803.1) Spaced lumber sheathing is not allowed in Seismic Design Category D 2. Flashing for asphalt shingles shall comply with this section. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. A base sheet that complies with the requirements of. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Section R803 Roof Sheathing R803.2 Wood Structural Panel Sheathing (Roof Online Note: This subsection covers plywood and OSB sheathing. Slate shingles shall be secured to the roof with two fasteners per slate. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. 2018 IRC. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. 2018 International Building Code (IBC) BASIC Upgrade to Premium CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES First Version: Aug 2017 All Codes I-Codes Legend Information Code Sections My Notes 2018 International Building Code (IBC) PREFACE arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right Modified bitumen roofing shall comply with the standards in Table R905.11.2. Galvanized fasteners shall be used for steel roofs. Wood shakes shall comply with the requirements of Table R905.8.5. Self-adhering polymer-modified bitumen. Roof Deck Requirements for Installation of Asphalt Shingles Technical . For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Install a nominal 4-inch-wide roof deck flashing tape over all roof sheathing panel seams and cover with #30 felt or equivalent synthetic underlayment. Brace gable end walls taller than 48. inches in height to resist wind forces by installing a framing assembly at each gable wall stud. Stainless steel fasteners are acceptable for metal roofs. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Install drip edges at eaves and rakes. Asphalt shingles shall comply with ASTM D3462. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. R905.2Asphalt shingles. 3. Paint systems in accordance with ASTM A 755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A 792, ASTM A 875, ASTM A 463, or ASTM A 653. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. . Asphalt shingles shall be fastened to solidly sheathed decks. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. 2018, 2021 IECC: Mass walls shall be in accordance with Section R402.2.5 (N1102.2.5 in 2018 IRC). Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Same as Maximum Ultimate Design Wind Speed, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Galvanized fasteners shall be used for steel roofs. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. Table 1 shows an insulation ratio - the R-value on the top of the roof sheathing compared to the total R-value. Sprayed polyurethane foam roofs shall have a design. Galvanized fasteners shall be used for steel roofs. Slate shingles shall be secured to the roof with two fasteners per slate. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions.