So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. 2. These clocks determine when your pool pump turns on, and how long it runs. The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. It would not reset itself and could not get power back to the timer. Only perform this step if you are qualified. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? PDF Model: T104 24 Hour Dial Time Switch It could also be loose wires, either on the time clock terminal board, or on the timer motor. You may need to adjust the meshing of the timer motor gear so it runs the clock. The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. So what would be the problem? On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. What do you suggest to do to get the cover up and the pillows back into position. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Tighten down all brass screws securely, to hold all wires firmly in place. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Trippers are not installed properly Re-install trippers on dial 2. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. MLS # 6354744 Pool Timer Clock Parts and Trippers },
The mechanism for the off tripper doesn't work at all when manually depressed. First time pool owner, Pool timer and trippers not working properly As you release the dial, you will feel the gears engage. Open following links to identify timer and then add a comment. Is this a bad timer mechanism or loose wire? I think I have found it. "headline": "Intermatic Pool Timer Troubleshooting",
First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. 2,767 Sq. In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Give it a little squirt of WD-40 or similar lubricant. #1. This will disengage the dial and allow you to spin it in either direction. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Until it came in, I manually turned on and the tripper turned it off. Articles and resources for swimming pool owners and DIYers. Could I send you a picture of my setup? Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. To set it, you just move the on/off "trippers" where you want them. Learn more about pool care and repair. You will have live wires exposed and they can kill you if you touch them. Hi Doug, Check the wiring. There's an issue with the wiring between the circuit breaker and the timer. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. Also be sure that the front dial is engaged with the gear located behind the dial. Perhaps you had a power outage during the night? Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Do not remove the screws from the trippers. The old "off" tripper was fractionally bent. If you use our referring links, it costs you nothing extra. Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Ordered new ones. Some of the replacement motors make it past quality control with the incorrect gear setup. Could be small bugs, or dirt, or both causing the problem. Is that a faulty motor? The trippers can also get damaged. I not sure if this is the best timer to use. For extra safety, shut-off the Pool breaker on the main home panel too. Ask Your Own Pool and Spa Question If they are not moving then you have an issue. Lately, the timer mechanism on my old T104R does not move. ), you should be able to discern if this is the problem, which could mean a new clock. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. 3 Baths. I have a Model T104P and have a new green on tripper attached. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. I have an Intermatic t104. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. Now remove the terminal cover on the timer. i have an oval pool that is closed for the winter but there ha been a problem. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. Intermatic Pool Timer Troubleshooting & Repair Guide - WeT HeaD Media Hi Joe, could be time, for new timer. Why is my water heater timer not working? - Quick-Advices "keywords": "",
Types of Pool Timers & How They Work - Pool Research I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
When the power goes out, the timer stops. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. Is it Necessary? Any guidance on how to fix this? For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Slide it around the pool timer dial to the correct start time and re-tighten it. Hi Carlos, is there a GFCI outlet in the circuit? "author": {
Please let me know if you find the solution! We cover T101, T103 and T104 models of mechanical pool timers. If you cant, is the manual switch stuck or jammed? Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. Advice? Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. TORK Repair Questions & Solutions, Tips & Guides - Fixya Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Hi there, "publisher": {
Things are working fine and all of a sudden the pool pump did not start in the morning. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Hi Mike, yes I sent you an email to your yahoo acct. my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . If the pump doesnt come on, follow the steps below. Dont know what the issue is. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting I bought a new timer and replace the T104 timer clock. Check that the TEST button has not popped out. In most cases like this, replacing the trippers is the solution. Is there a control board, PCB in the panel that could have problems? "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
A timer that switches on and off at the wrong times usually occurs after a power outage. Is the ON tripper all the way pushed onto the dial? Deep down, I figured it was something I did wrong and it was. We may earn a small commission. how should I lubricate those? The problem lies, where the power dies, as they say, Thanks for the response. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. Should I go ahead and spray it anyway? If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. What was the fix?? Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Tork timer not keeping time | Mike Holt's Forum Did you find the issue? Or be loose and not making good contact. If it doesnt, there could be an issue with the clock face or gears. Intermatic Pool Timer Troubleshooting - In The Swim Pool Blog If you find no answers readily apparent, then replace the timer mechanism they dont last forever! Is it keeping time normally? I just replaced my T101 timer 2 years ago. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. It is an ON tripper right? It loses about 1.5 to 2 hours per day without any outages. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) "image": {
I unscrewed the clip and put it back on and its still doing the same thing. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. No broken or loose wires visible. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. If after verifying you have power to the timer, then check these things to further troubleshoot. I believe its the manual on/off switch that is the problem. Above you said to connect white to A. and Black to 1what do I do with red? The yellow clock face should sit down in the timer. If its loose, grab a screwdriver and tighten it up. You will first want to look at the pool timer and see if you have two timer pins. My pump has a plug. Any idea what may be causing this? It is not warped in any way. Hi, new timer out of the box, 200V. See the next section in this article for that. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. This morning the customer said it wasn't turning off. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Still no luck. Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. It worked for a day but the day after it didnt work. My time clock has an ant infestation! David, check the wiring, the power in and power out wires may be reversed. ft. home is a 3 bed, 4.0 bath property. There should be an off pin and an on pin. Pool timer malfunction - DoItYourself.com Community Forums I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. Garden Guides | How to Troubleshoot a Swimming Pool Timer I need to replace a timer for my pool vacuum. View community ranking In the Top 5% of largest communities on Reddit. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. THE 10 CLOSEST Hotels to Time Tripper - tripadvisor.ca If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. This will disengage the dial from the . You will first need to adjust the time on the timer first. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. To do this, pull the yellow-faced time dial (clockface) toward you. Or is there anything else I can check? That should quiet it down. "@type": "ImageObject",
i would like to use a timer but am now afraid to try another. Everythings OK now, unit works just fine. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. You dont have two OFF trippers, right? Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. If all looks well, and the gears are still not turning, you may need to replace the mechanism. This is hard to check if you are not qualified. Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . Move the switch and see that they separate when off, and come together when on. I have a sweeper set on auto on the second timer and it is working correctly. Confused. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. I noticed that they had stopped. Read Book Tork Trippers Manual Guide Pdf For Free - twiki.skotos To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. I look through the window of the panel and see the gears running well. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. I have Model T40004RTe. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. A recent power outage will cause the timer to stop working. You can replace it but its really just easier to replace the entire mechanism. The 10 Best Pool Timers - Pool Care Guy Flip it from where it is now, to the opposite side. Clock not turning or making any sound. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. The most common pool timer used for inground pool pumps is the Intermatic time clock. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. screwfindinganame on June 18, 2013 at 11:36 pm After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. The circuit is protected by two ganged breakers. 12 Best Pool Pump Timers For Reducing Your Power Bill! My pool timer is in the off position and it is still running. For additional tripper pairs on CLOCK-DIALorder 156T1978A. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. It should loosen up after a few goes when the grease and gunt dissolve. That was probably what burned the plug. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. $829,900. Monday the clock face was free spinning, today when I got home it had broken and fallen off. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. Dead as a door nail. },
Why do we stock so many pool parts? Thanks in advanced. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). My timer works good it turns on and off when I set the time. Hi Casey, perhaps the cord or wires are broken? my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. If you dont have the voltage here you have an issue with either the wiring or the breaker. The trippers will "trip" the analog clock to turn on and off automatically at the set times. Black goes to _1 Off flipper always works. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. What Im wanting to do is just disable the turn off/on and just keep power 24/7. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Watch these tips and tricks before replacing it. Recently i just notice my T104R timer a bit noisier than usual. The clock is powered from the Line 1 terminal correct? Start with the easy checks. Turn the power off at the breaker box and carefully remove the wires to the clock. 2425 Glenview Dr, HOLLISTER, CA 95023 | MLS# ML81913834 | Redfin I would suggest calling Intermatic and suggesting that idea and a free replacement? The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. First, verify the power is turned off at the breaker panel. "@type": "Person",
It should sit down nicely. Theres really only 3 causes as to why your pump wont turn on/off. "url": "https://blog.intheswim.com/"
May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. Back when I was a young technician I was taught to always look for the easy things and use all my senses. "url": "https://intheswim.com/",
Phil. This page is fantastic!! If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. Stupid third question, but does the ON tripper say ON? Sometimes its way quick just to replace it rather than spend hours troubleshooting. PDF Model: PF1103T TIME CONTROL WITH FREEZE PROTECTION - Heritage Pools, LLC If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. Just replace it and hope for one that isnt defective. Intermatic T100 Series Replacement Trippers for Timers 156T1978A - The Now try to jiggle it on and off. Thanks. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Thanks for the suggestions.. This pool timer is waterproof, heavy-duty, and accurate. I noticed one thing that the power from the breaker is going into the control panel. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). We are on our third timer. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). }
. Or the switch can suffer wear over many years, and might not make solid contact. "datePublished": "1/10/2020",
You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Are the gears engaged, in the center, behind the dial? DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. Voltage is 243, frequency is 60hz. http://waterheatertimer.org/Tork-timers-and-manuals.html "address": "",
Then turn the breaker, that the time clock is connected to, off and back on again. How do you know if your pool timer is bad? My intermatic timer is about two years old as well. Or other advice or explanation. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. Also known as an RCD (residual current device) in Australia and the UK. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. IT happens, so I ask. OPEN TODAY, 12PM TO 3PM. It is still moving and it will trip off but not on. Found the answer. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. I called Intermatic and there is nothing you can do except check it every time you have a power loss. i have a P1121 intermatic timer connected to a hayward above ground pool pump. Donna Simpson Eating Website But What Toilet? So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. #9. I replaced the fuse(BUSS 300v GLR 3) as well. My intermatic pool timer will not automatically turn on. First you want to make sure there is actually power getting from the power board to the timer itself. Look into the visual motor check window, near the top of the timer mechanism. The 2,810 sq. Any suggestions on how to troubleshoot? Line is incoming, Load goes to the pump. The timer quit after a nearby lightning strike. Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. Simple Ways to Set a Pool Timer: 11 Steps (with Pictures) - wikiHow Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? If not, the motor may be failing. The back of the timer dog has a tab that flips the switch, check the alignment of both, the dog may not be contacting the switch with enough surface to flip it on? If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. The time does not advance after resetting. I looked to see if the gears on the timer are running. The on/off pins are tight and pretty new stillany thoughts? Turn the metal bar until it contacts one of two plastic side tabs. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. Hello Davy, Terry here again. Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. My pool pump and skimmer are on two different motors. The 12 Best Pool Timers of 2022 - WildRiver Align the bar with the current time and push it back into place. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. VIDEO TOUR. Hi Davy, Did you try to flip the switch of the timeclock? by pool co. , so wondered about the cost. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. Watch these tips and tricks before replacing it. Any ideas? Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. 975 Telegraph Rd #103, Santa Paula, CA 93060 | MLS# V1-15365 | Redfin Breakers go bad sometimes, after many years. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. It randomly loses the time that it is set to. Pools are not cheap! Any suggestions? It I set the timer again it will jeep time until it gets to the next dog ear. At some time the timer was disconnected and the pump wired direct to the breakers. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. Step 3 I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Why it always stop around 10pm by itself and not moving again? "@type": "Organization",
They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. I notice my pool pump was not on so I went and I hear timer running but no juice to the pool filter. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF.